GET THE APP

Titanium Dental Implant Hypersensitivity: A Review Article

Journal of Research in Medical and Dental Science
eISSN No. 2347-2367 pISSN No. 2347-2545

All submissions of the EM system will be redirected to Online Manuscript Submission System. Authors are requested to submit articles directly to Online Manuscript Submission System of respective journal.

Review - (2022) Volume 10, Issue 3

Titanium Dental Implant Hypersensitivity: A Review Article

Ali Robaian Alqahtani, Khalid Gufran*, Mohammed Alasqah, Abdullah Saad Alqahtani, Abdulaziz Alsakr and Abdullah Ali Alqahtani

*Correspondence: Khalid Gufran, Department of Conservative Dental Sciences, College of Dentistry, Prince Sattam Bin Abdulaziz University, Alkharj, Saudi Arabia, Email:

Author info »

Abstract

Titanium and its alloys have been the material of choice for dental implants since decades. Although, titanium is considered a biocompatible element reports of allergic reactions to titanium and its alloys have emerged over time. Whether dental implants can potentially induce hypersensitivity reactions or not is still debatable. The present paper discusses available literature on metal hypersensitivity including that induced by titanium and its alloys. It also discusses available tests for detection of metal hypersensitivity and the mechanisms through which titanium and its alloys may trigger hypersensitivity reactions in tissues, including that in the oral environment.

Keywords

Allergy, Dental Implant, Titanium, Hypersensitivity

Introduction

Titanium has been used widely in the field of medical as well as dental science especially as an intraosseous material, owing to its remarkable biocompatibility [1-3]. Apart from being biocompatible, titanium possesses several other favorable properties, one of which is its high resistance to corrosion [4]. Titanium when exposed to the external environment develops a thin oxide layer which makes it resistant to corrosion [5]. Biocompatibility and corrosion resistance coupled with other useful mechanical properties like low thermal conductivity, good ductility, high strength and low weight as compared to other metals,4 has helped titanium maintain its status as the material of choice in orthopedic as well as dental implants [6,7]. Though, it has been believed widely that titanium is non-allergenic material in nature, instances of hypersensitivity to titanium have been reported in the literature.

Roitt et al. [8] have defined a hypersensitivity reaction as “an acute immunological response that occurs when coming into contact with a known antigen.” Type IV hypersensitivity reactions have been seen to be associated with implant related allergic reactions [9]. It is a T-cell mediated response and may occur in hours to days of contact with the allergen, hence called delayed hypersensitivity.10 Hypersensitivity to implants has not been discussed much in dentistry, but some common symptoms which have been reported in the medical literature include edema, redness, urticaria, pruritus, and eczema [10-13]. Advanced symptoms include atopic dermatitis [14] and necrosis [13].

Dental and Orofacial Allergic Reactions

Dental and Orofacial allergic reactions usually manifest themselves in the form of oral mucosal erythema, purpura of the palate, hyperplastic gingivitis, loss of papillae of the tongue, angular cheilitis and lichenoid reactions [15,16]. In dental implants, facial erythema and proliferative hyperplastic tissue along the dental implant have been reported [17-20].

Titanium dental implants may release titanium ions into the periodontal ligament tissue, which is capable of causing inflammatory changes at and surrounding the area of the dental implant. This inflammatory reaction leads to the activation of macrophages which in turn release cytokines which are known biomarkers of diseases. These titanium ions combine with endogenous proteins to form antigens which lead to Type IV or delayed hypersensitivity reactions [16,21]. Several diagnostic tests have been introduced to test for allergens. Some of which are as follows:

Patch test: It is the most commonly used test to detect allergies to substances. It is also called the epicutaneous test. In this test the presumed allergen is applied on the skin of the patient preferably at the back. The skin exposed to the allergen is usually examined after 48 to 72 hours for the presence of any changes like redness, edema, vesicle formation etc. Titanium oxide has been used for such patch tests. 0.1-0.2% titanium sulfate solution and titanium chloride have also been suggested to be used as reagents in place of titanium oxide. Not many such studies have been conducted on dental implants and such tests have limited applicability due to their poor sensitivity in Type IV hypersensitivity reactions [16,22,23].

Prick test: It is usually employed to test Type I hypersensitivity reactions and gives quick results. The presumed allergen is injected intradermally and the area around the injection site is examined after 15 to 30 minutes. It lacks application in checking dental implant sensitivities [16,24].

Lymphocyte transformation test (LTT)/ Memory Lymphocyte Immuno Stimulation Assay (MELISA): Cells of the patients in vitro are exposed to the presumed allergen and T cell proliferation is observed.25 It relies on the incorporation of tritiated thymidine by the T cells.23 Some studies have also reported the occurrence of false-positive results in such tests. This tests had been greatly popularized in testing metal allergies in the past, but studies suggest otherwise [25,26].

Blood test: It may aid in detection of allergy to titanium [23].

Since, all these tests lack applicability in testing hypersensitivity to implant materials, there is a need to develop newer methods to detect allergies to metals used as implant materials.

Corrosion in Dental Implants

Titanium and its alloys have been considered to be fairly resistant to corrosion, yet reports of corrosion in titanium alloys have been documented in the literature. The different types of corrosion that titanium alloys may be prone to are as follows:

Galvanic corrosion: This is a common type of corrosion occurring in titanium implants which occurs due to contact of the titanium implant with that of other metallic restorations in the oral cavity. This results in the production of galvanic current and may also result in pain [27-30].

Crevice corrosion: It generally occurs due to the geometry of implant assembly. Localized crevice assault may occur on exposure of the implant to heat or solutions containing chloride, bromide or iodide ions during various procedures. There is increase in the concentration of these ions around the crevice which leads to decrease in the pH and finally degradation of the protective oxide layer around titanium, leading to the corrosion of the implant [30,31].

Erosion corrosion: This type of corrosion occurs when saliva containing corrosive compounds like food particles and certain enzymes, comes in contact with high velocity [32]. Titanium is relatively resistant to saliva and other fluids carrying suspended solids, therefore this type of corrosion occurs due to continuous attack of such corrosive fluid inducing local changes and removal of metal or cement material of the implant. This may additionally give rise to crevice or galvanic corrosion [27].

Stress corrosion cracking: This type of corrosion relies on a combination of three factors for its occurrence, namely tensile stress, an alloy susceptible to corrosion, and an environment conducive to corrosion. Tensile stresses may develop as a result of residual stresses during implant fabrication/ machining and functional/ occlusal loading. Implants may have minute crevices or pits which may be differentially exposed to stresses leading to stress corrosion cracking [27,33].

Even though it has been proved that titanium alloys exhibit better corrosion resistance as compared to Co–Cr and stainless steel alloys, their corrosion over time may result in dissolution and leaching out of titanium ions and other alloy materials like aluminium and molybdenum into the oral environment which may provoke a host response. This host response may induce cytokine production and hence hypersensitivity reactions [27,34].

Discussion

Titanium has become the material of choice for the fabrication of appliances in medical as well as dental field due to its extraordinary properties, especially. its biocompatibility. But, it is worth remembering that there exists no material which can be said to be ‘universally biocompatible’ [27,35]. When it comes to materials that are used in dentistry including implants it has been noted that dental biomaterials have the capacity to release certain substances that can potentially affect the oral environment and hence induce hypersensitivity reactions [27,36,37]. Therefore, the release of such substance, which are usually in the form of ions into the oral environment, their redistribution into the body of the patient and accumulation are major concerns related to the choice of material in dental implants. Also, the potential toxicity and risks associated with the release of ions in the oral environment and the body raise genuine health concerns since these implants are intended for lasting a lifetime. Such reactions will also affect the longevity of the implants [22,38]. Therefore, studies are now being increasingly conducted to check the hypersensitivity or allergic reactions caused by materials used for dental implants, esp. titanium and its alloys.

Allergic reaction to a metal is spawned by the reaction of metal ions with skin and mucosa or by corrosion of the concerned metal used, particularly in case of an implant. Metal ions often form bonds with native proteins to produce haptens which can elicit antibody production and hence allergic reactions. These ions also possess the potential to precipitate the degranulation of mastocytes and basophiles, which again may induce allergic reactions [9,39]. Foussereau et al. [40] were the first to report hypersensitivity in a patient to a steel orthopaedic fracture implant. Many identical reports of hypersensitivity reactions have been reported thereafter [5].

Bone loss induced by corrosion has been speculated to be a major cause of late loosening of implants [41] Lalor et al. [42] in their study discovered presence of huge amounts of titanium ions in failed hip implants of patients. They concluded that the primary factor behind the failure of these implants was allergic reaction to the titanium alloy used in the implants. They also found evidence of T-lymphocytes at the reaction site suggestive of Type IV hypersensitivity reaction. Witt et al. also documented failed hip implants due to corrosion. They reported that in the titanium implants another layer of TiO2 was formed rapidly following corrosion, a phenomenon termed as ‘repassivation’. A lot of TiO2 was formed at the implant site, so much so that the surrounding tissue turned black [42,43]. Huber et al. [41] established a link between implant corrosion and hypersensitivity. They performed microscopic examination of perimplant tissue from 11 patients with loose articular implants with unusual deposits. Evidence of hypersensitivity reaction was found in all the cases indicating a possible relationship between the two. Instances of allergic reaction to implanted pacemakers with titanium casing have also been documented by Yamauchi et al. [24], Sicillia et al. [1] used the cutaneous tests (Prick technique) to test Type I Hypersensitivity to titanium and epicutaneous tests to test for Type IV/ Delayed hypersensitivity on 35 patients. In the cutaneous tests, a drop of 1% and 5% titanium oxide was introduced to the skin on the forearm of the patient and a puncture in the skin was made using a lancet. Reaction to the titanium oxide was noted. In the epicutaneous tests, the same concentrations of titanium oxide were placed on the skin at the back of the patient and covered with a waterproof dressing. Reaction to the substance was noted at 24, 48 and 72 hours to check for signs of Type IV hypersensitivity. Eight patients in the study displayed positive tests.1However, it has been reported that cutaneous and epicutaneous tests are only effective in testing contact sensitivity to allergens and no standard patch test has yet been developed to test allergy to titanium [27].

Several factors contributing to oral implant failures have been reported in various studies. Tonetti et al. stated that peri-implant infection, biomechanical overload, or a combination of the two could be the possible factors involved in the late implant failures [44]. Piattelli et al. [45] proposed that infection of the surrounding implant tissue could be associated with early as well as late implant failures, loss of osseointegration without infection could be associated with late failures and fracture of the implants could be associated with late failures. Researchers over the years have classified implant failures in different ways. Esposito et al. [46] classified implant failure on the basis of biological, mechanical, iatrogenic and patientrelated factors.5 Additionally, increased risk of implant failures has been reported in patients with diabetes mellitus and those undergoing head and neck radiation therapy [47,48]. Preez et al. [49] authored a case report of implant failure due to hypersensitivity reaction to titanium. Egusa et al. [50] also reported presence of facial eczema suggestive of allergic reaction to a titanium implant over-denture in a patient.

Titanium alloys are the preferred choice instead of pure titanium in the construction of dental implants due to their greater strength. These alloys preferably contain aluminium and vanadium in addition to titanium, but other elements in smaller amounts may also be present in these alloys. These elements may serve as impurities and have been speculated to induce allergic reactions in several cases [51]. Harloff et al. [52] in their study performed a spectral analysis to assess the percentage of additional elements in titanium alloys which may act as potential allergens. They concluded that in all the examined titanium alloys certain elements other than aluminium and vanadium were invariably present. Common elements discovered in the titanium alloys were Nickel, Cobalt, Chromium, Beryllium, Copper, Iron and Palladium. Forte et al. [53] have highlighted various studies shedding light on the allergic potential of elements present consistently in titanium alloys. Many other studies elucidate the allergic potential of nickel, aluminium and beryllium [54-56]. On the contrary, Hasoki et al. [57] in a recent study examined 270 patients that visited a Dental Metal allergy Clinic for hypersensitivity to different metal allergens used in dental alloys. This included 4 titanium allergens as well. They placed the allergens on the skin at the back of these patients and sealed them with adhesive plaster. The skin of the patients was examined for signs of hypersensitivity at 2, 3 and 7 days after placement of the allergen. 80.4% of the 217 patients displayed positive allergic reaction to at least one of the allergens. Out of 270 patients 16 had dental implants. 11 patients displayed a positive allergic reaction to at least one of the allergens while 4 patients exhibited allergy to titanium allergens. Among the 270 patients, only 6.3% of the patients displayed hypersensitivity to titanium allergens [57], further asserting that most of the allergies to titanium alloys are a product of other metal impurities present in the alloy. On the contrary, Pioletti et al. [58] conducted a study to determine the cytotoxicity of various concentrations of commercially pure titanium (cp) on osteoblasts. They postulated that corrosion of titanium caused decrease in viability of osteoblasts which would in turn produce cytotoxic effects. Studies by Kwon et al. [59] and Wang et al. [60] have reiterated that prolonged experience to commercially pure titanium may produce cytotoxic effects. Also, Mine et al. [61] in their study indicated that prolonged exposure to titanium ions may adversely affect cells responsible for osseointegration including osteoblasts and osteoclasts. There is a lack of availability of epidemiological studies that demonstrate the prevalence of titanium hypersensitivity or hypersensitivity to titanium alloys in the general population [7].

Conclusions

Although, evidence-based studies on hypersensitivity to dental implant materials, especially titanium and its alloys are insufficient to prove that titanium dental implants are not biocompatible, yet reported instances of hypersensitivity induced by titanium and its alloys cannot be overlooked. Also, there is a need to develop tests that may accurately detect hypersensitivity to metals and alloys including that of titanium in the oral environment so that further studies on implant hypersensitivity may be conducted with ease. Clinicians should also check for hypersensitivity to titanium and its alloys in cases of implant failures.

Acknowledgement

The authors are grateful to the Deanship of Scientific Research, Prince Sattam Bin Abdulaziz University Alkharj.

References

  1. Sicilia A, Cuesta S, Coma G, et al. Titanium allergy in dental implant patients: a clinical study on 1500 consecutive patients. Clin Oral Implants Res 2008; 19:823-35.
  2. Indexed at, Google Scholar, Cross Ref

  3. Smith DC, Lugowski S, McHugh A, et al. Systemic metal ion levels in dental implant patients. Int J Oral Maxillofac Implants 1997; 12.
  4. Indexed at, Google Scholar

  5. Sykaras N, Iacopino AM, Marker VA, et al. Implant materials, designs, and surface topographies: their effect on osseointegration. A literature review. Int J Oral Maxillofac Implants 2000; 15.
  6. Indexed at, Google Scholar

  7. Jorge JR, Barao VA, Delben JA, et al. Titanium in dentistry: Historical development, state of the art and future perspectives. J Indian Prosthodont Soc 2013; 13:71-7.
  8. Indexed at, Google Scholar, Cross Ref

  9. Siddiqi A, Payne AG, De Silva RK, et al. Titanium allergy: could it affect dental implant integration?. Clinical Oral Implants Res 2011; 22:673-680.
  10. Indexed at, Google Scholar, Cross Ref

  11. Sarmiento-González A, Encinar JR, Marchante-Gayón JM, et al. Titanium levels in the organs and blood of rats with a titanium implant, in the absence of wear, as determined by double-focusing ICP-MS. Analyt Bioanal Chem 2009; 393:335.
  12. Indexed at, Google Scholar, Cross Ref

  13. Bilhan H, Bural C, Geckili O. Iifanium hypersensitivity. N Y State Dent J 2013; 39.
  14. Indexed at, Google Scholar

  15. RoittIM, Delves PJ. Essential Immunology. 11th Edn. 2006.
  16. Google Scholar

  17. Hallab N, Merritt K, Jacobs JJ. Metal sensitivity in patients with orthopaedic implants. JBJS 2001; 83:428.
  18. Indexed at, Google Scholar, Cross Ref

  19. Hensten-Pettersen A. Casting alloys: Side-effects. Adv Dent Res 1992; 6:38-43.
  20. Indexed at, Google Scholar, Cross Ref

  21. Peters MS, Schroeter AL, van Hale HM, et al. Pacemaker contact sensitivity. Contact Derm 1984; 11:214-218.
  22. Indexed at, Google Scholar, Cross Ref

  23. Thomas P, Bandl WD, Maier S, et al. Hypersensitivity to titanium osteosynthesis with impaired fracture healing, eczema, and T‐cell hyperresponsiveness in vitro: Case report and review of the literature. Contact Derm 2006; 55:199-202.
  24. Indexed at, Google Scholar, Cross Ref

  25. Haug RH. Retention of asymptomatic bone plates used for orthognathic surgery and facial fractures. J Oral Maxillofac Surg 1996; 54:611-617.
  26. Indexed at, Google Scholar, Cross Ref

  27. Tamai K, Mitsumori M, Fujishiro S, et al. A case of allergic reaction to surgical metal clips inserted for postoperative boost irradiation in a patient undergoing breast-conserving therapy. Breast Cancer 2001; 8:90-92.
  28. Indexed at, Google Scholar, Cross Ref

  29. Vamnes JS, Lygre GB, Grönningsæter AG, et al. Four years of clinical experience with an adverse reaction unit for dental biomaterials. Community Dent Oral Epidemiol 2004; 32:150-157.
  30. Indexed at, Google Scholar, Cross Ref

  31. Chaturvedi TP. Allergy related to dental implant and its clinical significance. Clin Cosmet Investig Dent 2013; 5:57.
  32. Indexed at, Google Scholar, Cross Ref

  33. Bircher AJ, Stern WB. Allergic contact dermatitis from titanium spectacle frames. Contact Derm 2001; 45:244-245.
  34. Indexed at, Google Scholar, Cross Ref

  35. Matthew IR, Frame JW. Ultrastructural analysis of metal particles released from stainless steel and titanium miniplate components in an animal model. J Oral Maxillofac Surg 1998; 56:45-50.
  36. Indexed at, Google Scholar, Cross Ref

  37. Matthew I, Frame JW. Allergic responses to titanium. J Oral Maxillofac Surg 1998; 12:1466-7.
  38. Indexed at, Google Scholar, Cross Ref

  39. Mitchell DL, Synnott SA, VanDercreek JA. Tissue reaction involving an intraoral skin graft and CP titanium abutments: A clinical report. Int J Oral Maxillofac Implants 1990; 5.
  40. Indexed at, Google Scholar

  41. Gulati K, Guhathakurta S, Joshi J, et al. Cytokines and their role in health and disease: A brief overview. MOJ Immunol 2016; 4:1-9.
  42. Indexed at, Google Scholar, Cross Ref

  43. Okamura T. A skin patch test for the diagnosis of titanium allergy. J Dent Res 1999; 78:1135.
  44. Indexed at, Google Scholar

  45. Goutam M, Giriyapura C, Mishra SK, et al. Titanium allergy: A literature review. Indian J Dermatol 2014; 59:630.
  46. Indexed at, Google Scholar, Cross Ref

  47. Yamauchi R, Morita A, Tsuji T. Pacemaker dermatitis from titanium. Contact Derm 2000; 42:52.
  48. Indexed at, Google Scholar

  49. Cederbrant K, Hultman P, Marcusson JA, et al. In vitro lymphocyte proliferation as compared to patch test using gold, palladium and nickel. Int Arch Allergy Immunol 1997; 112:212-7.
  50. Indexed at, Google Scholar, Cross Ref

  51. Koene RA. The'memory lymphocyte immunostimulation assay'(MELISA) is useless for the detection of metal allergy. Ned Tijdschr Geneeskd 2005; 149:2090-2.
  52. Indexed at, Google Scholar

  53. Vijayaraghavan V, Sabane AV, Tejas K. Hypersensitivity to titanium: A less explored area of research. J Indian Prosthodont Soc 2012; 12:201-207.
  54. Indexed at, Google Scholar, Cross Ref

  55. Leinfelder KF, Lemons JE. Clinical restorative materials and techniques. Lea & Febiger 1988.
  56. Lucas LC, Lemons JE. Biodegradation of restorative metallic systems. Adv Dent Res 1992; 6:32-7.
  57. Indexed at, Google Scholar, Cross Ref

  58. Holgers KM, Roupe G, Tjellstroöm A, et al. Clinical, immunological and bacteriological evaluation of adverse reactions to skin‐penetrating titanium implants in the head and neck region. Contact Derm 1992; 27:1-7.
  59. Indexed at, Google Scholar, Cross Ref

  60. Sato N. 1989 Whitney Award lecture: Toward a more fundamental understanding of corrosion processes. Corrosion 1989; 45:354-68.
  61. Indexed at, Google Scholar, Cross Ref

  62. Gat N, Tabakoff W. Effects of temperature on the behavior of metals under erosion by particulate matter. J Test Eval 1980; 8:177-86.
  63. Indexed at, Google Scholar, Cross Ref

  64. Jones DA. Forms of corrosion recognition and prevention. NACE Houston 1982; 19-43.
  65. Google Scholar

  66. Rogers SD, Howie DW, Graves SE, et al. In vitro human monocyte response to wear particles of titanium alloy containing vanadium or niobium. J Bone Joint Surg 1997; 79:311-5.
  67. Indexed at, Google Scholar, Cross Ref

  68. Flatebø RS, Johannessen AC, Grønningsæter AG, et al. Host response to titanium dental implant placement evaluated in a human oral model. J Period 2006; 77:1201-10.
  69. Indexed at, Google Scholar, Cross Ref

  70. Schmalz G, Garhammer P. Biological interactions of dental cast alloys with oral tissues. Dent Material 2002; 18:396-406.
  71. Indexed at, Google Scholar, Cross Ref

  72. Schedle A, Örtengren U, Eidler N, et la. Do adverse effects of dental materials exist? What are the consequences, and how can they be diagnosed and treated?. Clin Oral Implants Res 2007; 18:232-56.
  73. Indexed at, Google Scholar, Cross Ref

  74. Olmedo DG, Paparella ML, Brandizzi D, et al. Reactive lesions of peri-implant mucosa associated with titanium dental implants: A report of 2 cases. Int J Oral Maxillofac Surg 2010; 39:503-7.
  75. Indexed at, Google Scholar, Cross Ref

  76. Schramm M. Clinical relevance of allergological tests in total hip replacement. In: Willmann G, editor. Bioceramics in Hip Joint Replacement Proceedings 5th International CeramTec Symposium. 2nd Edn. New York, USA: Thieme Publishers; 2017; 101–6.
  77. Google Scholar

  78. Foussereau J, Laugier P. Allergic eczemas from metallic foreign bodies. Transactions of the St. John's Hospital Derm Soc 1966; 52:220-225.
  79. Indexed at, Google Scholar

  80. Huber M, Reinisch G, Trettenhahn G, et al. Presence of corrosion products and hypersensitivity-associated reactions in periprosthetic tissue after aseptic loosening of total hip replacements with metal bearing surfaces. Acta Biomater 2009; 5:172-80.
  81. Indexed at, Google Scholar, Cross Ref

  82. Lalor PA, Revell PA, Gray AB, et al. Sensitivity to titanium. A cause of implant failure?. J Bone Joint Surg1991; 73:25-28.
  83. Indexed at, Google Scholar, Cross Ref

  84. Witt JD, Swann M. Metal wear and tissue response in failed titanium alloy total hip replacements. J Bone Joint Surg 1991; 73:559-63.
  85. Indexed at, Google Scholar, Cross Ref

  86. Tonetti MS, Schmid J. Pathogenesis of implant failures. Periodontol 1994; 4:127-38.
  87. Indexed at, Google Scholar, Cross Ref

  88. Piattelli A, Scarano A, Piattelli M. Histologic observations on 230 retrieved dental implants: 8 years' experience (1989–1996). J Periodontol 1998; 69:178-84.
  89. Indexed at, Google Scholar, Cross Ref

  90. Esposito M, Hirsch JM, Lekholm U, et al. Biological factors contributing to failures of osseointegrated oral implants (II). Etiopathogenesis. Eur J Oral Sci 1998; 106:721.
  91. Indexed at, Google Scholar, Cross Ref

  92. Morris HF, Ochi S, Winkler S. Implant survival in patients with type 2 diabetes: Placement to 36 months. Ann Periodontol 2000; 5:157-65.
  93. Indexed at, Google Scholar, Cross Ref

  94. Granströ GÖ, Tjellströ A, Brånemark PI, et al. Bone-anchored reconstruction of the irradiated head and neck cancer patient. Otolaryngol Head Neck Surg 1993; 108:334-43.
  95. Indexed at, Google Scholar, Cross Ref

  96. Du Preez LA, Swart TJ, Butow KW. Implant failure due to titanium hypersensitivity/allergy?-Report of a case: Implantology corner. South African Dent J 2007; 62:22-5.
  97. Indexed at, Google Scholar

  98. Egusa H, Ko N, Shimazu T, et al. Suspected association of an allergic reaction with titanium dental implants: A clinical report. J Prosthetic Dent 2008; 100:344-7.
  99. Indexed at, Google Scholar, Cross Ref

  100. Javed F, Al‐Hezaimi K, Almas K, et al. Is titanium sensitivity associated with allergic reactions in patients with dental implants? A systematic review. Clin Implant Dent Related Res 2013; 15:47-52.
  101. Indexed at, Google Scholar, Cross Ref

  102. Harloff T, Wolfgang H, Holzwarth U, et al. Titanium allergy or not?. Health 2010; 2:306.
  103. Google Scholar

  104. Forte G, Petrucci F, Bocca B. Metal allergens of growing significance: Epidemiology, immunotoxicology, strategies for testing and prevention. Inflamm Allergy Drug Targets 2008; 7:145-162.
  105. Indexed at, Google Scholar, Cross Ref

  106. Schuh A, Thomas P, Kachler W, ET AL. Allergic potential of titanium implants. Orthopedist 2005; 34:327-8.
  107. Indexed at, Google Scholar, Cross Ref

  108. Böhler‐Sommeregger K, Lindemayr H. Contact sensitivity to aluminium. Contact Derm 1986; 15:278-81.
  109. Indexed at, Google Scholar, Cross Ref

  110. Skowron F, Grezard P, Berard F, et al. Persistent nodules at sites of hepatitis B vaccination due to aluminium sensitization. Contact Derm 1998; 39:135-6.
  111. Indexed at, Google Scholar, Cross Ref

  112. Hosoki M, Nishigawa K, Tajima T, ET AL. Cross-sectional observational study exploring clinical risk of titanium allergy caused by dental implants. J Prosthod Res 2018; 62:426-431.
  113. Indexed at, Google Scholar, Cross Ref

  114. Pioletti DP, Takei H, Kwon SY, ET AL. The cytotoxic effect of titanium particles phagocytosed by osteoblasts. J Biomed Material Res 1999; 46:399-407.
  115. Indexed at, Google Scholar, Cross Ref

  116. Kwon SY, Takei H, Pioletti DP, ET AL. Titanium particles inhibit osteoblast adhesion to fibronectin‐coated substrates. J Orthop Res 2000; 18:203-11.
  117. Indexed at, Google Scholar, Cross Ref

  118. Wang ML, Nesti LJ, Tuli R, ET AL. Titanium particles suppress expression of osteoblastic phenotype in human mesenchymal stem cells. J Orthop Res 2002; 20:1175-84.
  119. Indexed at, Google Scholar, Cross Ref

  120. Mine Y, Makihira S, Nikawa H, ET AL. Impact of titanium ions on osteoblast-, osteoclast-and gingival epithelial-like cells. J Prosthod Res 2010; 54:1-6.
  121. Indexed at, Google Scholar, Cross Ref

Author Info

Ali Robaian Alqahtani, Khalid Gufran*, Mohammed Alasqah, Abdullah Saad Alqahtani, Abdulaziz Alsakr and Abdullah Ali Alqahtani

Department of Conservative Dental Sciences, College of Dentistry, Prince Sattam Bin Abdulaziz University, Alkharj, Saudi Arabia
 

Citation: Ali Robaian Alqahtani, Khalid Gufran, Mohammed Alasqah, Abdullah Saad Alqahtani, Abdulaziz Alsakr, Abdullah Ali Alqahtani, Titanium Dental Implant Hypersensitivity: A Review Article, J Res Med Dent Sci, 2022, 10 (3):84-89.

Received: 01-Mar-2022, Manuscript No. JRMDS-22-46779; , Pre QC No. JRMDS-22-46779 (PQ); Editor assigned: 03-Mar-2022, Pre QC No. JRMDS-22-46779 (PQ); Reviewed: 17-Mar-2022, QC No. JRMDS-22-46779; Revised: 21-Mar-2022, Manuscript No. JRMDS-22-46779 (R); Published: 28-Mar-2022

http://sacs17.amberton.edu/